Big Drinking Water Treatment System Reverse Osmosis Machine
Project: 38m3/h secondary reverse osmosis (RO) pure water system
Raw water: local municipal tap water (no water quality report)
Terminal water production requirements: water production ≥38m3/h
Product water quality requirements: electrical conductivity of terminal production ≤3.0μs/cm
This technical general rule is used in the reverse osmosis + EDI desalination system of this project. It puts forward the technical requirements of the system's functional design, results, performance, installation and debugging.
Even if the purchaser does not specify all the technical requirements and applicable standards, the supplier shall provide a set of high-quality products and corresponding services that meet the requirements of this technical program and the listed standards. High mandatory standards for national security and environmental protection must meet their requirements.
The process and equipment involved in this quotation meet the following requirements:
Raw water quality: local municipal tap water (no water quality report)
System water production:
Pretreatment: 65m3/h
Grade 1 RO water production: 45m3/h
Secondary RO water production: 38m3/h
Terminal water supply: 38m3/h
Water quality:
First-level RO outlet water conductivity: ≤10μs/cm (inlet water conductivity ≤300μs/cm)
Conductivity of secondary RO effluent: ≤3.0μs/cm
38T/H 2 stage Water treatment plant Product description
1. Host Dimension:400*150*210CM;Weight about:32000kg;
2. Water production:38T/H,raw water TDS≤1000ppm,Pure water : TDS≤1ppm;
3. Raw water quality: tap water (see water quality report);
4.Power:Three-phase 380V;Frequency:50±0.5HZ(Choose); Rated total power:90kw;Normal working power:80kw.
5. Installation conditions: indoor installation, temperature:5-45ºC;
Fuction of this reverse osmosis system?
This system is a 38m3/h secondary reverse osmosis purified water preparation system. The raw water is pre-pretreated and then subjected to secondary RO reverse osmosis treatment. Most of the particles, colloids, organic impurities, heavy metal ions, Bacteria, viruses, heat sources and other harmful substances and 99% dissolved salt meet the terminal water requirements.
This system as a whole, each treatment process is related to each other, the effect of the previous treatment process may affect the next level of treatment process, and each link may affect the terminal water production of the entire system. Therefore, the configuration of the entire system Design in strict accordance with customer requirements.
The whole set of equipment has two operating modes: automatic and manual. Under normal working conditions, the equipment can operate continuously and automatically without manual guards. Including: normal water production; automatic physical cleaning of reverse osmosis membrane components; automatic shutdown of the pure water tank when full of water; EDI high and low pressure protection, protection of influent water, and discharge of product water; automatic start-up and supplementation of ultrapure water storage tanks at low water levels; High-pressure pump low-voltage protection and over-voltage protection, electrical equipment lack phase protection, etc.
RO System Design Basis
1.Raw water source :Salty water...TDS<1000PPM
2.Raw water analysis report : unconfirmed
3.RO system rated flux : 38m3/h
4.RO system recovery : 50-65%
5.Salt rejection : 96%
6.RO working voltage : 380V/50Hz
7.Water feeding pressure : 0.15-0.25Mpa
Specifications
NO. |
DESCRIPTION |
Origin/Brand |
QTY |
1 |
Raw Water Pump |
CNP |
2sets |
2 |
Reverse osmosis desalination device water production: 38.0m3 / h, desalination rate: 96 ~ 99%, the system water utilization: 50% |
|
2sets |
3 |
Cleaning system |
CHUNKE |
1set |
4 |
Electronic control system (China's Mitsubishi PLC automatic control, the French Schneider Electric components, RO membrane automatic washing, the original water tank and pure water tank water level control automatically stop the machine, low pressure, high pressure, overheating, overcurrent, lack of protection and Alarm function, reserved manual operation function and 4-20mA signal output) |
CHUNKE |
1sets |
38T/H 2 stage Water treatment plant details pictures:
Electronic Parts:
PLC programmable automatic control is Mitsubishi,if you want PLC touch screen panel, we use driver Siemens or Danfoss.
All electronic parts are France Schneider contactors, thermal relays, knobs, switches, lights, Korean pressure controller, time controller.
Why is Reverse Osmosis a Good Water Filtration Option?
We've been in the water filtration business since 2000 and have found Reverse Osmosis filtration to consistently be
one of the best ways to achieve superior water for the home and business.
RO system is key part for the water treatment system, which is widely used to make the pure water and drinking water. RO membrane removes many types of large molecules and ions from solutions by applying pressure to the solution when it is on one side of a selective membrane. The result is that the solute such as iron, Virus, bacteria and solids is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the other side.
Packing and shipping
Packed in carton case and wooden box.
Delivery: Negotiation
About our company
Guangzhou Chunke Environmental Technology Co., Ltd is a scientific enterpruise, which is specialized in water treatment equipment and accessories of research and development, production, sales and service.
Production and management: Cartridge filter, bag filter, mechanical filter, lon Exchanger, Imitation FRP barrels, ozone mixing tower, sterile water tank, stainless steel membrane shells, hollow-fiber mambrane, ultraviolet radiation sterialization device, ozone generator, and water treatment equipment and so on.