Certification: ISO9001, CE
Salt Rejection Rate: 98.0%
Application: Industry
Capacity: 3t/H
Motive Force: Electric Power
Type: Reverse Osmosis
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Basic Info.

Model NO.
CK-RO-6T
Usage
Environmental Protection, Chemical Industry
Function
Water Purification
Technique
Membrane Separation Technology
RO Membrane Brand
Dow, Ge, Toray and Other Brand
Control Mode
Automatic
Material
FRP, Ss
Place of Origin
Guangzhou
Size
230*70*165cm
Single Gross Weight
2000kg
Recovery Rate
55-65%
Desalination
96-98%
Power
5.2kw
Package Material
Wooden Case, Machine RO Reverse Osmosis Water
Transport Package
Wooden Packing
Specification
CE
Trademark
CHUNKE
Origin
Guangdong(China)
HS Code
8421299090
Production Capacity
10 Sets/ Month

Product Description

 
Double Pass Reverse Osmosis Water Treatment Machine Marine Water Desalination
PRODUCT INTRODUCTION
The company's CK-RO series reverse osmosis device for electronics power plants pharmaceutical petroleum chemical food and beverage and printing fields to provide high quality water reverse osmosis pure water technology is the most advanced the most economic and the most effective system in water treatment industry which is a process to push high-content salt water reverse into lower salt water by press water into ro membrane. By this most hazardous substances heavy metalsoluble soild are wiped off. Then only water molecule can go through the ro membrane to be pure water.

Double Pass Reverse Osmosis Water Treatment Machine Marine Water Desalination

Benefits of Reverse Osmosis (RO) Systems
RO system requires very less energy for its working.
It requires very low maintenance.
The RO system uses an automated technique called cross-flow to clean its clogged membrane.
RO system, when used in water filters, eliminates 98% of the impurities from tap water.
The water produced by RO technology, when supplied to a gas turbine, improves operating efficiency, and increases output by more than 10%.
RO systems are cost-effective, and their price is continually decreasing.
RO systems do not make use of harmful chemicals, hence are used in many power plants.

Material of reverse osmosis system?
We have different material for different application. Before   choosing RO System and Type please contact with our Pro-fessional CHUNKE technical service.

1. Tanks: Fiber glass or Stainless Steel 304/316
2. Pipes: U-PVC or stainless steel filter
3. Frame: Stainless Steel 304 or 316
4. Filter Housing: U-PVC or SS304 or SS316
5. Membrane Housing: FRP or SS304 or SS316

Of course, every application is unique and we want to make sure you find the exact solution that you are looking for, so reach out to CHUNKE professional and ask all the questions you have to find your industrial water filtration solution.

Double Pass Reverse Osmosis Water Treatment Machine Marine Water DesalinationDouble Pass Reverse Osmosis Water Treatment Machine Marine Water Desalination

PRODUCT INTRODUCTION
Raw water (tap water. surface waterunderground water) pass pretreatment system,sophisticated filterand then goes to reverse osmosis by high pressure pump to produce pure water directly is known as one-stage reverse osmosis.One stage reverse osmosis is suitable for the raw water with conductivity less than 500uS/cm and conductivity output wateris1-10uS/cm

What is different for Gallon and Liter ?  1gallon=3.785 liter  1m3=1000 liter= 1ton 

Reverse osmosis water treatment plant is a equipment that uses the pressure difference of semi-permeable membrane to purify water.  Reverse osmosis membrane can effectively remove most organic matter, harmful substances, bacteria, particles in raw water.  Suitable for industrial waste water, sewage filtration, effective removal of most substances on the water quality, in order to meet the standard water quality requirements
Double Pass Reverse Osmosis Water Treatment Machine Marine Water Desalination
Double Pass Reverse Osmosis Water Treatment Machine Marine Water DesalinationDouble Pass Reverse Osmosis Water Treatment Machine Marine Water DesalinationDouble Pass Reverse Osmosis Water Treatment Machine Marine Water Desalination

[ we are real manufacturer in water treatment industry over 30 years ]

How to choose the right water treatment unit?

1) First you need to tell us what your source of raw water is.
2) It is better to provide a raw water quality report
3) What kind of water quality requirements should be achieved.
4) How many liters per hour does a desalination plant need?

Pre-sale service
- Counseling and support!
- Technical communication, provide drawing confirmation!
- Real case feedback!
- Factory visit to see the prototype

After-sales service
* We provide installation/commissioning/training.
Train employees how to install and use machines.
* Prompt answers to questions 24 hours a day.
* 12 months free warranty, even after the warranty period, we will help fix the problem.
Arrange engineers to repair machinery overseas.

Workshop production
1. Purchase and customize raw materials and make them according to drawings
2. Machine assembly, polishing and welding, wire link complete according to the standard
3. Arrange test inspection before delivery to ensure normal operation of the machine
4. Detailed label display at a glance
5. Complete the production and packaging of water treatment reverse osmosis equipment within the delivery period


Double Pass Reverse Osmosis Water Treatment Machine Marine Water Desalination
Buying guide:
We are more than happy to provide you with the best quality products and services.  In order to provide you with a qualified quotation, we need the following information:  
 
Capacity: What is your water treatment requirement?  We need to know your handling capacity in order to provide you with the most accurate quotation.  
Water Quality Requirements: What are your water quality requirements?  We need to know your water quality in order to provide you with the most suitable reverse osmosis equipment.  
Scope of application: What industry is water treatment applied to? For example, chemical industry, printing and dyeing industry, bottled water, hotel water, boiler water, etc., different industries of different water quality, we have corresponding solutions
Installation Location: Where does your water treatment equipment need to be installed?  We need to know your installation location to provide you with a correct installation solution and device layout.  

 
Please provide the above information and we will provide you with a qualified quotation as soon as possible.  If you need more information or have any questions, please feel free to contact us.  

What is different for Gallon and Liter ?  1gallon=3.785 liter  1m3=1000 liter= 1ton 

Reverse osmosis water treatment plant is a equipment that uses the pressure difference of semi-permeable membrane to purify water.  Reverse osmosis membrane can effectively remove most organic matter, harmful substances, bacteria, particles in raw water.  Suitable for industrial waste water, sewage filtration, effective removal of most substances on the water quality, in order to meet the standard water quality requirements

 
Several consumables require regular replacement.  
Material Replace time suggestion Package weight
Quartz sand Max. every 15-18 months 50kg/bag
Activated Carbon Max.  every 15-18 months 25 kg/bag  
Resin Max.  every 15-18 months 25 l/bag
PP filter element about once a month to replace /
Reverse osmosis membrane Max. every 2 years /
* It is recommended that customers purchase 1-2 years PP filter element with the machine.  Because PP filter element needs to be replaced every month, belongs to consumables, and the replacement frequency depends on the quality of water.



Double Pass Reverse Osmosis Water Treatment Machine Marine Water DesalinationDouble Pass Reverse Osmosis Water Treatment Machine Marine Water DesalinationDouble Pass Reverse Osmosis Water Treatment Machine Marine Water Desalination